TMS용 굴뚝 먼지측정기 : P-5C

with cover-right side

without cover

without cover-left side

without cover-right side

Technology

The P-5C particulate Monitor performs continuous non-extractive mass concentration measurements-simple and reliably – in a wide variety of application.
Mounts to standard ASA flange with NO requirements for alignment or oposit wall access, resulting in low installation costs.
Complete with internal zero and reference calibrations, purge system, and protective covers.
Comes with integral purge system and protective covers.
Installs in minutes, operated and calibrated by nono-skilled plant personal.



Specification

-Measurement Range : 1 - 20,000 mg/Actual m³

-Scale range (mg/Am³) : Dual rangein, user selectable anywhere within measurement range 1~20,000mg/m³

-Detection limit : 0.5 mg/Am³

-Stability : Zero Drift

-Short term (2 Hr) - less than 1% full scale

-Long term (24 Hr) - less than 2% full scale

-Zero and Span Drift

-Short term (2 Hr) - less than 2% of total scale

-Long term (24 Hr) - less than 5% full scale

-Response time : Approximately 3 seconds

-Light-scatterers in the LED beam, the traceable scatter is supplied with an external calibration tube.

-Ambient Temperature : -30ºC to 55ºC

-Process gas temperature : To +260ºC standard, to +375ºC with high temperature probe option

-Process gas pressure : To +130mm H2O standard

-To +375mm H2O w/high volume purge blower option

-Process gas velocity : instrument operation is independent of gas velocity.

-Power requirement : 110V+15V 50/60Hz 6A or 220V 50/60Hz 3A